Atago 1.0000 to 1.0600 Urine specific gravity Refractometer, PAL-10S
Roll over image to zoom zoom_in
- Weight: 100 Grams
- Product Type: Clinical Refractometer
- Range: 1.0000 to 1.0600
- Resolution: 0.0001
- Accuracy: ±0.001
- receiptGST Invoice
- headphonesCustomer Service
- lockSecure Payments
- policyReturns & Warranty
- home_pinOrder Tracking
- paymentsBuy in Installments
₹38774.8 (Incl. of all taxes)
₹32860+ ₹5914.8 GST (18%)
7 Business Days
1 Pcs
90275020
picture_as_pdfDownload Product Leafletkeyboard_double_arrow_right
picture_as_pdfBrand Authorization Certificatekeyboard_double_arrow_right
picture_as_pdfDownload Bosch Cataloguekeyboard_double_arrow_right
picture_as_pdfBrand Authorization Certificatekeyboard_double_arrow_right
picture_as_pdfDownload Bosch Cataloguekeyboard_double_arrow_right
Highlights
The PAL-10S is a digital hand-held compact refractometer to measure urine S.G. To operate it, simply place a drop of urine on the prism top and press the "Start"key. Then, the urine S.G. value will be displayed on the LCD instantly. If the kidneys have any disease or decreased function, the water content in the body cannot be regulated and the urine’s specific gravity value will differ from the standard value. The decrease in the body’s ability to properly concentrate urine will result in highly concentrated or severely low concentrated urine, which is linked to certain health problems.
Urine specific gravity over 1.026 is a sign of danger!
Notes:
Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.
Features:
- It is useful for determining renal failure and diabetes.
- Only a small amount of sample is required
- Measurement only takes a few seconds.
- Automatically compensated for temperature variance.
- IP65 Water resistant: Can be washed under running water.
Urine Specific Gravity Values:
Urine specific gravity over 1.026 is a sign of danger!
- Standard Range: 1.009 ~ 1.025
- High Value (1.026~): Dehydration, Renal Insufficiency Anuria, Fluid Restriction
- Low value (~1.008): Too much fluid intake, Diabetes Insipidus, kidney failure, pyelonephritis
Fair and Square Competition:
- In doping testing, for urine samples over 150ml or more, the expected specific gravity is over 1.0003. For urine samples that are over 90ml but under 150ml, the expected specific gravity is 1.005. ATAGO’s urine specific gravity meter plays a role in making sure that the athlete’s hard work will be rewared.
Measurement Method:
![]() | Step 1: Place a few drops of sample on the prism |
![]() | Step 2: Press the Start key. |
![]() | Step 3: Displays results in about 3 secondes. |
Applications:
- Hospital Clinical Labs
- Clinical Laboratories
- Hospital Wards (Urology)
- Emergency and Urgent Care Clinics
- Testing and Managing Urine Concentration
- Hospitals / Clinics
- Mass Screening Centers
- Prevention of dehydration for athletes
- Doping Test
- Hydration Assessment
- Animal Hospitals
Why choose the ATAGO?
- Proud Heritage and Experience: ATAGO has over 70 years of experience in optical instrument manufacturing. With our expertise cultivated over decades, as well as an extensive selection of instruments, we can meet a variety of measurement needs including highly specialized industries.
- Industry-Leading Technology: Refraction of light has been our sole specialty throughout the existence of ATAGO and we strive for perfection in optical systems. We listen to end-user feedback from 154 countries and continuously push the limit of refractometry.
- Trusted Product Support: We dedicate ourselves on the high durability and low failure rate of ATAGO products. Our repair service is carried out in a timely manner. Calibration certificates are available.
- Made with Japanese Quality
Notes:
- All ATAGO products are designed and manufactured in Japan.
- ATAGO products comply with HACCP, GMP, and GLP system standards.
- Specifications and appearance are subject to change without notice.
Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.
Specifications
| SKU | LA.RE.CL.00001 |
|---|---|
| Product Type | Clinical Refractometer |
| Model No | PAL-10S |
| Range | 1.0000 to 1.0600 |
| Resolution | 0.0001 |
| Accuracy | ±0.001 |
| Temperature Compensation | 10 to 35°C |
| Sample Volume | 2 to 3 Drops |
| Measurement Time | About 3 seconds |
| Power Supply | 2x AAA Batteries |
| International Protection Class | IP65 Water resistant |
| Cat.No. | 4410 |
| Dimensions (cm) | 5.5 x 3.1 x 10.9 cm |
You May Also Like
Shop By Related Categories
Atago 1.0000 to 1.0600 Urine specific gravity Refractometer, PAL-10S
Visit Atago Store keyboard_double_arrow_right₹38774.8 (Incl. of all taxes)
₹32860+ ₹5914.8 GST (18%)



