Fluke 106 6000 Counts / 600V Palm-Sized Digital Multimeter

Shop all Fluke

SKU: HA.AU.MU.00003

Model: Fluke106

Roll over image to zoom zoom_in
  1. Fluke 106 6000 Counts / 600V Palm-Sized Digital Multimeter
  2. Fluke 106 6000 Counts / 600V Palm-Sized Digital Multimeter
  3. Fluke 106 6000 Counts / 600V Palm-Sized Digital Multimeter
  4. Fluke 106 6000 Counts / 600V Palm-Sized Digital Multimeter
  5. Fluke 106 6000 Counts / 600V Palm-Sized Digital Multimeter

  • Weight: 200 Grams
  • Product Type: Multimeter
  • Display (LCD) : 6000 counts, updates 3/sec
  • Operating: 2000 Mtr
  • Storage: 12000 Mtr
See all product information chevron_right
  • receiptGST Invoice
  • headphonesCustomer Service
  • lockSecure Payments
  • policyReturns & Warranty
  • home_pinOrder Tracking
  • paymentsBuy in Installments

5964.9 (Incl. of all taxes)

5055+ ₹909.9 GST (18%)

MRP ₹7434

SAVE 32%



3 Business Days

1 Pcs

90303100

picture_as_pdfDownload Product Leafletkeyboard_double_arrow_right
picture_as_pdfBrand Authorization Certificatekeyboard_double_arrow_right
picture_as_pdfDownload Bosch Cataloguekeyboard_double_arrow_right

Highlights

The Fluke 106 digital multimeter is made to fit the way you work! It is designed to fit in the palm of your hand and go with you no matter where your job takes you.

Features:

  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A and current
  • Data hold.


What's Included In This Package:

  • Fluke 106 Palm-sized Digital Multimeter
  • Tl75 Hard Point Test Lead Set
  • 2 AAA Batteries (Installed)
  • User’s Manual


Accuracy Specifications:

 Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of ±([% of Reading] + [Number of Least Significant Digits]
 
FunctionRangeResolutionAccuracy
AC Volts
(40 Hz to 500Hz)1
6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
1.0 % + 3
DC Volts6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
0.5 % + 3
AC Millivolts600.0 mV0.1 mV3.0 % + 3
Diode Test22.000 V0.001 V10 %
Resistance
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3
Capacitance350.00 nF
500.0 nF
5.000 μF
50.00 μF
500.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
Frequency4 Hz
(10 Hz – 100 kHz)
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
NA
Duty Cycle41 % to 99 %0.1 %NA
AC Current
(40 Hz to 200 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
DC Current4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
  • All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
  • Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
  • Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).
  • All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
FunctionOverload ProtectionInput Impedance (Nominal)Common Mode Rejection RatioNormal Mode Rejection Ratio
AC Volts600 V 1>10 MΩ <100 pF 2>60 dB at dc,
50 Hz or 60 Hz
\AC Millivolts600 mV>1M, <100 pF>80 dB at 50 Hz or 60 Hz
DC Volts600 V 1>10 MΩ <100 pF>100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
  1. 6 x 105 V Hz Max
  2. For mV (AC), input impedance is approximately 1 MΩ.
Relative Humidity
Operating HumidityNon-condensing when <10°C
≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C
Operating Humidity, 40 MΩ Range≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C
Altitude
Temperature Coefficient0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Size (HxWxL)142 mm x 69 mm x 28mm
IP RatingIEC 60529: IP 40
SafetyIEC 61010-1: 600 V CAT III, Pollution Degree 2
Electromagnetic EnvironmentIEC 61326-1: Portable
Electromagnetic CompatibilityApplies to use the Korea only.  Class A Equipment (Industrial Broadcasting and Communication Equipment)1
This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes.

Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.

Specifications

SKUHA.AU.MU.00003
Product TypeMultimeter
Model NoFluke106
Maximum Voltage Between any Terminal and Earth Ground 600 V
Display (LCD) 6000 counts, updates 3/sec
Battery Type 2 AAA, NEDA 24A, IEC LR03
Battery Life 200 hours minimum
Temperature Operating 0 °C to 40 °C
Temperature Storage -30 °C to 60 °C
Operating 2000 Mtr
Storage 12000 Mtr
Fuse Protection for Current Inputs 11A, 1000V Fast Fuse Fluke specified part only