Fluke 1503 0.01M - 2000M Ohms Insulation Resistance Meter

Shop all Fluke

SKU: HA.AU.IN.00003

Model: Fluke1503

Roll over image to zoom zoom_in
  1. Fluke 1503 0.01M - 2000M Ohms Insulation Resistance Meter
  2. Fluke 1503 0.01M - 2000M Ohms Insulation Resistance Meter

  • Weight: 550 Grams
  • Product Type: Insulation Testers
  • Measurement range: 0.01 M to 2000 M Ohms
  • Test voltage: 500 V, 1000 V
  • Short circuit current : 1 mA nominal
See all product information chevron_right
  • receiptGST Invoice
  • headphonesCustomer Service
  • lockSecure Payments
  • policyReturns & Warranty
  • home_pinOrder Tracking
  • paymentsBuy in Installments

51981.36 (Incl. of all taxes)

44052+ ₹7929.36 GST (18%)

MRP ₹64782

SAVE 32%



3 Business Days

1 Pcs

90303900

picture_as_pdfDownload Product Leafletkeyboard_double_arrow_right
picture_as_pdfBrand Authorization Certificatekeyboard_double_arrow_right
picture_as_pdfDownload Bosch Cataloguekeyboard_double_arrow_right

Highlights

Fluke 1503 Insulation Resistance Tester handles all the basic insulation testing needs The Fluke 1503 is a great choice for basic residential and commercial electrical insulation testing. This rugged, compact tool fits in the palm of your hand.

The 1503 is the same form factor as the Fluke 1507 but with a few less features. You can count on it to handle the most common tests at a most affordable price. Additional features, like the remote probe, reduce the time needed to perform repetitive testing.


Features:

  • A rugged, compact insulation resistance tester for residential and commercial electricians
  • Performs insulation tests from 0.01 M Ohms to 2000 M Ohms
  • Offers two insulation test voltages: 500 V and 1000 V
  • Includes live circuit detection to prevent insulation test if voltage >30 V is detected
  • Measures resistance from 0.01 Ω to 20.00 kΩ.


Other Useful Capabilities:

  • Measures AC/DC voltage from 0.1 V to 600 V
  • Includes auto-discharge of capacitive voltage for added user protection
  • Provides lo-ohms earth-bond continuity (200 mA)
  • Simplifies repetitive or hard-to-reach testing with the remote test probe
  • Saves battery power with auto power off
  • Presents results on a large, backlit display
  • Features CAT IV 600 V overvoltage category rating
  • Comes with remote probe, test leads, test probes, alligator clips, and one-year warranty
  • Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work
  • Runs on four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests


What's Included In This Package:

  • Fluke 1503 Insulation Resistance Tester
  • Remote probe
  • Test leads
  • Test probes
  • Alligator clips
  • User documentation
 
AC/DC Voltage Measurement
AccuracyRange600.0 V
Resolution0.1 V
50 Hz to 400 Hz ±(% of Rdg + Digits)±(2% + 3)
Input impedance3 MΩ (nominal), < 100 pF
Common mode rejection ratio (1 kΩ unbalanced)> 60 dB at DC, 50 or 60 Hz
Overload protection600 V rms or DC
Earth Bond Resistance Measurement
Range/Resolution20.00 Ω0.01 Ω
200.0 Ω0.1 Ω
2000 Ω1.0 Ω
20.00 kΩ0.01 kΩ
Accuracy±(1.5% + 3)
Overload protection2 V rms or DC
Open circuit test voltage> 4.0 V, < 8 V
Short circuit current> 200.0 mA
Insulation Specifications
Measure accuracy
500 V±(1.5% + 5)
1000 V±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ
General Specifications
Temperature coefficient0.05 x (specified accuracy) per °C for temperatures < 18°C or > 28°C (< 64°F or > 82°F)
Relative humidity
0% to 95% @ 10°C to 30°C (50°F to 86°F)
0% to 75% @ 30°C to 40°C (86°F to 104°F)
0% to 40% @ 40°C to 55°C (104°F to 131°F)
Electromagnetic compatibilityIn an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997)
SafetyComplies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)
CertificationsCSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition
Battery llifeInsulation test use:Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Resistance measurements:Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.
Size (H x W x L)5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
IP ratingIP40
AltitudeOperating2000 m CAT IV 600 V, 3000 m CAT III 600 V
Non-operating (storage)12,000 m
Included accessoriesTL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe

Please Note that Products may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.

Specifications

SKUHA.AU.IN.00003
Product TypeInsulation Testers
Model NoFluke1503
Measurement range 0.01 M to 2000 M Ohms
Test voltage 500 V, 1000 V
Test voltage accuracy + 20%, - 0%
Short circuit current 1 mA nominal
Auto discharge Discharge time < 0.5 second for C = 1 µF or less
Live circuit indicator Inhibit test if terminal voltage > 30 V prior to initialization of test
Maximum capacitive load Operable with up to 1 µF load
Measure accuracy 500 V / 1000 V
Maximum voltage applied to any terminal 600 V AC rms or DC
Storage temperature -40°C to 60°C (-40°F to 140°F)
Operating temperature -20°C to 55°C (-4°F to 131°F)
Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
Shock 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)
Batteries Four AA batteries (NEDA 15A or IEC LR6)
Over-range capability 110% of range

Shop By Related Categories

Fluke 1503 0.01M - 2000M Ohms Insulation Resistance Meter

Visit Fluke Store keyboard_double_arrow_right

51981.36 (Incl. of all taxes)

44052+ ₹7929.36 GST (18%)

MRP ₹64782

SAVE 32%