Fluke 15B Max-02 6000 Counts / 600V Economical Digital Multimeter With TL31 Extra-Slim Test Leads

- Weight: 455 Grams
- Product Type: Multimeter
- Display (LCD): 6000 counts, updates 3/sec
- Battery Type: 2 AA, IEC LR6
- Battery life: 500 hours minimum
- Ingress Protection: IP40
- Altitude: Operating 2000 Mtr; Storage 12000 Mtr
- receiptGST Invoice
- headphonesCustomer Service
- lockSecure Payments
- policyReturns & Warranty
- home_pinOrder Tracking
- paymentsBuy in Installments
₹11646.6 (Incl. of all taxes)
₹9870+ ₹1776.6 GST (18%)
MRP ₹14514
SAVE 32%
3 Business Days
1 Set
90303100
picture_as_pdfBrand Authorization Certificatekeyboard_double_arrow_right
picture_as_pdfDownload Bosch Cataloguekeyboard_double_arrow_right
Highlights
Fluke 15B MAX Inherits and continues the classic design of 15B+, with further improved functions: Input Alert Alarm, Simple interface to wake meter from sleep mode by activating any buttons, test leads with fine probes to help electricians and electronic R&D personnel make accurate measurements.
Features:
- Audible and visual alarm for incorrect connections
- Test leads with fines tips for circuit board testing
- Simple interface to wake meter from sleep mode by activating any buttons
- Voltage: 6000-count reading
- Capacitance range: 2000uF
- Safety rating: CATIII 600V
What's Included In This Package:
- TL31 Extra-Slim Test Leads with 2 Protective Caps
- 2 AA Batteries
- Safety information
Accuracy Specifications:
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 % Accuracy specifications take the form of: ± ([% of Reading] + [Number of Least Significant Digits]).
Function | Range | Resolution | Accuracy | |
15B MAX | 17B MAX | |||
AC Volts (40 Hz to 500 Hz)1 | 6.000 V 60.00 V 600.0 V 1000 V | 0.001 V 0.01 V 0.1 V 1 V | 1.0 % + 3 | 1.0 % + 3 |
AC Millivolts | 600.0 mV | 0.1 mV | 3.0 % + 3 | 3.0 % + 3 |
DC Volts | 6.000 V 60.00 V 600.0 V 1000 V | 0.001 V 0.01 V 0.1 V 1 V | 0.5 % + 3 | 0.5 % + 3 |
DC Millivolts | 600.0 mV | 0.1 mV | 1.0 % + 10 | 1.0 % + 10 |
AC Current μA (40 Hz to 400 Hz)2 | 400.0 μA 4000 μA | 0.1 μA 1 μA | 1.5 % + 3 | 1.5 % + 3 |
AC Current mA (40 Hz to 400 Hz)2 | 40.00 mA 400.0 mA | 0.01 mA 0.1 mA | 1.5 % + 3 | 1.5 % + 3 |
AC Current A (40 Hz to 400 Hz)2 | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 | 1.5 % + 3 |
DC Current μA2 | 400.0 μA 4000 μA | 0.1 μA 1 μA | 1.5 % + 3 | 1.5 % + 3 |
DC Current mA2 | 40.00 mA 400.0 mA | 0.01 mA 0.1 mA | 1.5 % + 3 | 1.5 % + 3 |
DC Current A2 | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 | 1.5 % + 3 |
Diode Test3 | 2.000 V | 0.001 V | 10% | 10% |
Temperature 4 | 50.0 °C to 400.0 °C 0 °C to 50.0 °C -55.0 °C to 0 °C | 0.1 °C | NA | 2 %+1 °C 2 °C 9 %+2 °C |
Resistance (Ohms)5 | 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ | 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 | 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 |
Capacitance6 | 40.00 nF 400.0 nF 4.000 μF 40.00 μF 400.0 μF 2000 μF | 0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF | 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 | 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
Frequency1 (10 Hz to 100 kHz) | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz | NA | 0.1 % + 3 |
Duty Cycle1 | 1% to 99% | 0.10% | NA | 1 % typical7 |
Continuity Threshold | — | — | 70Ω | 70Ω |
Backlight | — | — | Yes | Yes |
|
Input Characteristics | ||||
Function | Overload Protection | Input Impedance (Nominal) | Common Mode Rejection Ratio | Normal Mode Rejection Ratio |
AC Volts | 1000 V 1 | >10 MΩ, <100 pF | >60 dB at 50 Hz or 60 Hz | — |
AC Millivolts | 1000 V 1 | >1 MΩ, <100 pF | >80 dB at 50 Hz or 60 Hz | — |
DC Volts | 1000 V 1 | >10 MΩ, <100 pF | >100 dB at 50 Hz or 60 Hz | >60 dB at 50 Hz or 60 Hz |
DC Millivolts | 1000 V 1 | >1 MΩ, <100 pF | >80 dB at 50 Hz or 60 Hz | — |
1106 V Hz max |
General Specifications: | |
Temperature | Operating 0 °C to 40 °C; Storage -30 °C to 60 °C |
Relative Humidity | Operating Humidity Non-condensing (<10 °C); ≤90 % RH at 10 °C to 30 °C; ≤75 % RH at 30 °C to 40 °C |
Fuse protection for current inputs | 440 mA, 1000 V, fast-blow, use only Fluke specified parts. 11 A, 1000 V, fast-blow, |
Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.
Specifications
SKU | ME.EL.MU.00098 |
---|---|
Product Type | Multimeter |
Model No | Fluke15BMax02 |
Maximum voltage between any Terminal and Earth Ground | 600 V |
Maximum differential voltage between V and COM terminals | 1000V |
Display (LCD) | 6000 counts, updates 3/sec |
Battery Type | 2 AA, IEC LR6 |
Battery life | 500 hours minimum |
Ingress Protection | IP40 |
Electromagnetic Environment | IEC 61326-1: Portable |
Size (HxWxL) | 183 mm x 91 mm x 49.5 mm |
Operating Humidity, 40 M Ohms range | =80 % RH at 10 °C to 30 °C; =70 % RH at 30 °C to 40 °C |
Altitude | Operating 2000 Mtr; Storage 12000 Mtr |
Temperature Coefficient | 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) |
Safety | IEC 61010-1, IEC61010-2-030: CAT III 600 V, Pollution Degree 2 |