Kusam-Meco 3-5/6 Digits 6000 Counts TRMS Digital Insulation Multimeter (23 Functions 73 Ranges), KM 877

Shop all Kusam-Meco

SKU: ME.EL.MU.00166

Model: KM877

Roll over image to zoom zoom_in
  1. Kusam-Meco 3-5/6 Digits 6000 Counts TRMS Digital Insulation Multimeter (23 Functions 73 Ranges), KM 877

  • Weight: 635 Grams
  • Product Type: Multimeter
  • Update Rate: 5 Per Second Nominal
  • Operating Temperature: -10ºC ~ 40ºC
See all product information chevron_right
  • receiptGST Invoice
  • headphonesCustomer Service
  • lockSecure Payments
  • policyReturns & Warranty
  • home_pinOrder Tracking
  • paymentsBuy in Installments

25157.6 (Incl. of all taxes)

21320+ ₹3837.6 GST (18%)

MRP ₹26650

SAVE 20%



3 Business Days

1 Pcs

90303100

picture_as_pdfDownload Product Leafletkeyboard_double_arrow_right
picture_as_pdfBrand Authorization Certificatekeyboard_double_arrow_right
picture_as_pdfDownload Bosch Cataloguekeyboard_double_arrow_right

Highlights

  • VFD V & Hz readings
  • Paper White Backlight LCD Display
  • Record MAX / MIN readings
  • Display Hold Function
  • Dual Digital Display
  • PI & DAR Function
  • Autoranging
  • Pass /Fail Insulation Resistance Compare function; 12 selectable Preset Values
  • LOCK-Test mode for Insulation Resistance & Earth Continuity Test
  • BeepJack ™ audible & visible input warning
  • Remote Probe for Insulation Resistance & Earth Continuity Test
  • Functions: DC/AC Voltage, VFD AC Voltage, Insulation Resistance, Resistance, Earth Continuity Test, Hz Line Level Frequency
  • Auto or Manual-ranging mode
  • Auto Power Off
  • Earth Continuity Test: 110mA @20 Ω range, 220mA @2.0 Ω range. The tester can perform at least 3000 Earth Continuity Test measurements with new alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on & 25 seconds off.
  • Relative Humidity: Maximum relative humidity 90% for temperature up to 28°C decreasing linearly to 50% relative humidity at 40°C.
  • Temperature Coefficient: Nominal 0.15 x (specified accuracy)/ °C @(-10°C~18°C or 28°C~40°C), or otherwise specified


Insulation Resistance @ 1mA Test Current:

  • 50V output Voltage: 25mA
  • 100V output Voltage: 45mA
  • 250V output Voltage: 85mA
  • 500V output Voltage: 170mA
  • 1000V output Voltage: 440mA
  • Tester can perform at least 950 Insulation Tests with new alkaline batteries at room temperature.
  • These are standard tests of 1000V into 1MΩ with a duty cycle of 5 seconds on and 25 seconds off.


Safety:

  • Double Insulation Per IEC/UL/EN61010-1 Ed. 3.0, IEC/EN61010-2-030 Ed. 1.0, IEC/EN61010-2-033 Ed. 1.0, IEC/UL/EN61010-031 Ed. 1.1 and CAN/CSA-C22.2 No. 61010-1-12 Ed. 3.0 to CAT III 1000 V AC & DC and CAT IV 600V AC & DC.
  • Compliance to IEC/EN61557; 2007 (per CE requirements, not certified by UL or ETL): IEC/EN61557-1, IEC/EN61557-2 & IEC/EN61557-4 where applicable.
  • E.M.C: Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11) In an RF field of 3V/m: Total Accuracy = Specified Accuracy + 25 digits. Performance above 3V/m is not specified.
  • Overload Protections: Earth Continuity Test - 0.25A/1KV, IR 30kA or better / V: 1100Vrms / mV, Ω & Others: 1000 Vrms


Package Content:

  • Multimeter
  • Test probe pair
  • BRP21S2-C Remote probe
  • Alligator clip pair
  • Holster
  • User manual
  • Carrying Case


Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.

Specifications

SKUME.EL.MU.00166
Product TypeMultimeter
Model NoKM877
Sensing AC, True RMS
Display 3-5/6 Digits 6000 Counts Backlight LCD Display
Polarity Automatic
Update Rate 5 Per Second Nominal
61 Segments Analog Bar Graph 60 Per Second Max
Power Supply 4 x Alkaline AA Batteries
Power Consumption 4.5mA Typical Except: ACV +Hz & VFD ACV +Hz: 7.0mA
Operating Temperature -10ºC ~ 40ºC
Pollution Degree 2
IP Rating IP40
Storage Temperature -20ºC ~ 60ºC, < 80% R.H. (With Battery Removed)
Altitude Operating Below 2000m
Low Battery 4.6V
APO Timing Idle For 20 Minutes
APO Consumption 50µA Typical
Dimension (LxWxH) 208 x 103 x 64.5 mm

Shop By Related Categories

Kusam-Meco 3-5/6 Digits 6000 Counts TRMS Digital Insulation Multimeter (23 Functions 73 Ranges), KM 877

Visit Kusam-Meco Store keyboard_double_arrow_right

25157.6 (Incl. of all taxes)

21320+ ₹3837.6 GST (18%)

MRP ₹26650

SAVE 20%