Metravi 0 - 100kV Manually Operated Oil Test Set, 100-OTS
Roll over image to zoom zoom_in
- Product Type: Oil Testing
- Output: 0 - 100Kv
- Frequency: 50Hz
- Input: 230/240V single phase AC supply
- receiptGST Invoice
- headphonesCustomer Service
- lockSecure Payments
- policyReturns & Warranty
- home_pinOrder Tracking
- paymentsBuy in Installments
₹67540.84 (Incl. of all taxes)
₹57238+ ₹10302.84 GST (18%)
MRP ₹84173
SAVE 32%
5 Business Days
1 Set
84212900
picture_as_pdfDownload Product Leafletkeyboard_double_arrow_right
picture_as_pdfBrand Authorization Certificatekeyboard_double_arrow_right
picture_as_pdfDownload Bosch Cataloguekeyboard_double_arrow_right
picture_as_pdfBrand Authorization Certificatekeyboard_double_arrow_right
picture_as_pdfDownload Bosch Cataloguekeyboard_double_arrow_right
Highlights
This set is useful for testing dielectric strength of the insulating oils normally used in distribution and high voltage transformers. The application of a particular strength of oil is specified in the IS books as per IS standard specifications. As per IS standard this test is for one minute.
Features:
- It is ideal for speedy and accurate testing of di-electric strength of transformer and circuit beaker oil under test room condition in accordance with IS:6792-1972 for oil testing.
- Output: Continuously variable from 0 to 50kV AC with centre point of the HV winding earthed
- Manually Operated
Interlocking:
- Zero start interlocking
- HT chamber door interlocking
Safety Measures:
- Zero interlocking arrangement before energizing HT transformer after each test.
- A transparent protective hood on the test cup with a interlocking micro switch for operator safety so that the HV transformers cannot be energized or remain energized when the transparent protective hood is opened.
Package Content:
- Cable 3 core of 3m length 5 Amp. Capacity of 3 pin plug for input supply
- Oil cell with electrode & spare gap
Type | Manual operated to uniformly increase the output voltage between 0 to 50 KV 'or' 60KV 'or' 70 KV 'or' 75 KV 'or' 80 KV 'or' 90 KV 'or' 100 KV 'or' 120KV with the help of continuously variable Autotransformer. |
Output | 0-50 KV 'or' 60KV 'or' 70 KV 'or' 75 KV 'or' 80 KV 'or' 90 KV 'or' 100 KV 'or' 120KV with center tap earthed infinitely variable. (For Example the output shall be 50kV for a 50kV Oil Test Set, the output shall be 60kV for a 60kV Oil test Set, so on and so forth) |
Max. generated test voltage (a. Between transformer) | 50KV 'or' 60 KV 'or' 70 KV 'or' 75 KV 'or' 80 KV 'or' 90 KV 'or' 100 KV 'or' 120 KV Rms. (For Example the Maximum terminals generated test voltage between transformer terminals shall be 50kV for a 50KV Oil Test Set and shall be 60kV for a 60KV Oil Test Set, so on and so forth) |
Max. generated test voltage (b. Between transformer) | 25KV 'or' 30 KV 'or' 35 KV 'or' 37.5 KV 'or' 40 KV 'or' 45 KV 'or' 50 KV 'or' 60 KV Rms. (For Example the maximum terminals & earth. voltage generated between the transformer terminals and earth shall be 25kV for a 50kV Oil Test set and shall be 30kV for a 60kV Oil Test Set, so on and so forth) |
Capacity | 500VA 'OR' 600VA 'OR' 700VA 'OR' 750VA 'OR' 800VA 'OR' 900VA 'OR' 1000VA 'OR' 1200VA intermittent. (For example the capacity shall be 500VA for a 50kV Oil Test Set and 600VA for a 60kV Oil Test Set, so on and so forth) |
Metering | Volt meter panel meter marked 0-50KV 'OR' 0-60KV 60 KV 'or' 70 KV 'or' 75 KV 'or' 80 KV 'or' 90 KV 'or' 100 KV 'or' 120 KV should indicate the applied voltage to liquid dielectric and also have memory effect. For example in a 60kV Oil Test Set the Voltmeter range shall be 60kV, so on and so forth |
Auxiliaries | The unit will have necessary switches, fuses indicating lamps, push button operated contactor etc. for efficient operation of unit |
Electrodes | Brass polished spherical electrodes Diameter mounted on a horizontal axis which can be set to a gap of 2.5 mm. Or 4mm |
Construction | Naturally air cooled. Portable sheet metal casting. Provided with handles consisting of control section and HT transformer in single cubicles |
Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.
Specifications
SKU | ME.EL.OI.00015 |
---|---|
Product Type | Oil Testing |
Model No | 100OTS |
Output | 0 - 100Kv |
Frequency | 50Hz |
Input | 230/240V single phase AC supply |
Duty | Intermittent duty cycle |
ISS reference | IS: 6792/1972 latest |
Indication | Mains ON and HT ON indicating NEON Lamps. Red lamp |
Test Cell | Methyl Methacrylate cell having effective volume between 300 to 500 ml |
Transformer | Resin encapsulated HT transformer |
Nature of Cooling | The transformer is cast resin type air cooled |
Capacity | Spread over a range from 500VA to 1200VA depending on the output voltage |