Metravi 5 Digit 0.5% Accuracy mV Thermocouple & RTD Source Calibrator, 01+

Shop all Metravi

SKU: ME.EL.PR.00054

Model: 01+

Roll over image to zoom zoom_in
  1. Metravi 5 Digit 0.5% Accuracy mV Thermocouple & RTD Source Calibrator, 01+
  2. Metravi 5 Digit 0.5% Accuracy mV Thermocouple & RTD Source Calibrator, 01+

  • Weight: 0.5 Kg
  • Product Type: Process Calibrators
  • Display: LCD
  • Power Consumption: 3V
  • No of Batteries: 2
See all product information chevron_right
  • receiptGST Invoice
  • headphonesCustomer Service
  • lockSecure Payments
  • policyReturns & Warranty
  • home_pinOrder Tracking
  • paymentsBuy in Installments

21133.8 (Incl. of all taxes)

17910+ ₹3223.8 GST (18%)

MRP ₹26338

SAVE 32%



5 Business Days

1 Pcs

90308990

picture_as_pdfDownload Product Leafletkeyboard_double_arrow_right
picture_as_pdfBrand Authorization Certificatekeyboard_double_arrow_right
picture_as_pdfDownload Bosch Cataloguekeyboard_double_arrow_right

Highlights

5 Digits 0.5% Accuracy, Source for Volt, Resistance, Pt-100, Cu-50, Thermocouples R, S, B, E, K, J, T, N types.

Features:

  • Provides analogue output for eight types of thermocouples (R, S, K, E, J, T, B, N) two types of thermo-resistance
  • (Cu 50 / PT-100), DC Voltages and resistance
  • °C and °F scales selectable
  • Suitable for the field use
  • High Accuracy of 0.05%
  • Sensor Type: B-Type Sensor, E-Type Sensor, J-Type Sensor, K-Type Sensor, N-Type Sensor, R-Type Sensor, RTD Sensor, S-Type Sensor, T-Type Sensor


What's Included In This Package:

  • User’s Manual,
  • Industrial testing lead CF-36 (clips for probe)


Technical Specifications:

  • Accuracy is specified for a period of one year after calibration, at 23±5ºC, with relative humidity to 75%.
  • Accuracy specifications are given as: ± ([% of reading] + [number of least significant digits]) (“Counts” refers to the number of increments or decrements of the least significant digit).
  • Note 1: Affiliated resistance of test lead is excluded
  • Note 2: The range of incentive current is from 0.05mA to 3mA, and the maximum output is less than or equals to 2V
  • Note 3: The accuracy does not include the error of interior temperature compensation sensor the range of interior temperature compensation sensor is from -10 to 50°C, and the error compensation is less than or equals to 0. 5ºC
OutputRangeOutput rangeResolutionAccuracyIllustration
DCV100mV-10.00 ~ 110.00mV0.01mV0.05%+ 30uVMax. output current ±2mA
100mV-100.0 ~ 1100.0mV0.1mV0.05%+0.3mV
OMH400Ω0.0 ~ 400.0Ω0. 1Ω0.05%+0.2Ω±0.5 ~ ±3mA Note 1, Note 2
4000Ω0 ~ 4000Ω0.05%+0.2Ω±0.05 ~ ±0.3 mA Note 1, Note 2
TCR-40 ~ 1760ºC1°C 0.05%+3°C
(less than or equals to 100°C)
0.05%+2°C (more than 100°C
Employs ITS-90 temperature
standard Note 3
S-20 ~ 1760°C1°C
B400 ~ 1800°C1°C 0.05%+3°C (400~600°C )
0.05%+2°C (more than 600°C)
E-200.0 ~ 1000.0°C0.1°C0.05%+2°C
(less than or equals to -100°C)
0.05%+1°C
(more than -100°C)
K-200.0 ~ 1370°C0.1°C
J-200.0 ~ 1200.0°C0.1°C
T-200.0 ~ 400.0°C0.1°C
N-200.0 ~ 1300.0°C0.1°C
RTDCu10-10.0°C ~ 250.0°C0.1°C0.05%+0.6°CIncentive current is ±0.5 ~ ±3 mA
when the incentive current is
±0.1 ~ 0.5 mA , add 0.5°C
additional error
Cu50-50.0°C ~ 150.0°C0.1°C0.05%+0.6°C
Pt10 385-200.0°C ~ 850.0°C0.1°C0.05%+0.6°C
Pt100 385-200.0°C ~ 850.0°C0.1°C0.05%+0.6°C
Pt200 385-200°C ~ 630°C0.1°C0.05%+0.6°CIncentive current is ±0.05 ~ ±0.3 mA
Pt500 385-200°C ~ 630°C0.1°C0.05%+0.6°C
Pt1000 385-200.0°C ~ 630.0°C0.1°C0.05%+0.6°C

Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.

Specifications

SKUME.EL.PR.00054
Product TypeProcess Calibrators
Model No01+
Colour Blue-Black
Display LCD
Power Consumption 3V
Power Source Battery Operated
Battery Type Alkaline
Battery Size AA
No of Batteries 2
Storage humidity range = 90%RH
Storage temperature range = - 10°C ~ 55°C
Operation humidity range = 80%RH
Operation temperature range 0°C ~ 50°C
Maximum Permitted Voltage 30V (within terminals or between terminal and earth ground)
Measurement 180 (L) × 90 (W) ×47 (D) mm (with protector)
Temperature coefficient 0.1 × (dedicated accuracy) %/ºC (5ºC ~ 18ºC , 28ºC ~ 40ºC)
Certifications Complies with IEC1010 (safety standard issued by International Electrician Committee)