Sanwa 6000 Count TRMS Digital Clamp Meter, DCM600DR

Shop all Sanwa

SKU: ME.EL.CL.00198

Model: DCM600DR

Roll over image to zoom zoom_in
  1. Sanwa 6000 Count TRMS Digital Clamp Meter, DCM600DR
  2. Sanwa 6000 Count TRMS Digital Clamp Meter, DCM600DR
  3. Sanwa 6000 Count TRMS Digital Clamp Meter, DCM600DR
  4. Sanwa 6000 Count TRMS Digital Clamp Meter, DCM600DR

  • Weight: 260 Grams
  • Product Type: Clamp Meters
  • Display: 6000 Count
  • Sampling Rate: 3 Times / Sec.
See all product information chevron_right
  • receiptGST Invoice
  • headphonesCustomer Service
  • lockSecure Payments
  • policyReturns & Warranty
  • home_pinOrder Tracking
  • paymentsBuy in Installments

19824 (Incl. of all taxes)

16800+ ₹3024 GST (18%)



7 Business Days

1 Pcs

90303390

picture_as_pdfDownload Product Leafletkeyboard_double_arrow_right
picture_as_pdfBrand Authorization Certificatekeyboard_double_arrow_right
picture_as_pdfDownload Bosch Cataloguekeyboard_double_arrow_right

Highlights

This DCM600DR can measure a maximum of 600 Amperes of AC/DC current. It can measure AC/DC current up to 600 Volts, the resistance of 999.9Ω, and perform continuity tests with a buzzer alarm. This device is suitable for current and voltage measurements of low-voltage circuitry, electric equipment, and power supply facilities. The device offers various functions such as data hold, peak hold, zero, etc. It features a 6000-count display with a back-light feature. The device also has an auto-power save feature that turns the screen off after 30 minutes of no use.


Features:

  • AC/DC current measurable max. 600A & DMM function
  • True RMS
  • 6000 count LCD with Backlight
  • Data hold
  • Relative value
  • Peak hold (1ms)
  • Auto power save (30min after the last operation) (non-cancelable)


Technical Data:

FunctionRangeAccuracyResistanceInput Impedance
DCA / ACA60/600A±(2%+5)0.01A-
DCV600V±(1%+2)0.1V1MΩ
ACV±(1.2%+5)
Resistance999.9Ω±(1%+7)0.1Ω-
Continuity
  • Buzzer sounds at less than 40Ω
  • Open voltage: Approx. 2.9V
 
True RMS
AC current and voltage of a non-sine wave can be measured by True RMS (Root-Mean-Square) values.
Continuity Buzzer
The buzzer sounds when the measuring object is electrically conducting.
Data Hold
A value indicated on the display is fixed for reference even after the test lead is removed.
Data Hold
A value indicated on the display is fixed even after the test lead is removed, and can be used as a record for reference purposes.
Peak Hold
The peak value like in-rush current is indicated. The minimum pulse width capturable differs according to models.
Auto Power Save
The display disappears to bring the device into the power-save state when a certain time has passed after power-up. Some models have a function to cancel this function.
Backlight
Backlit display allows indicator reading in a dark place.
Relative Value
A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
AC/DC Amperage
Measure Both AC & DC Amps.

Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.

Specifications

SKUME.EL.CL.00198
Product TypeClamp Meters
Model NoDCM600DR
Display 6000 Count
Sampling Rate 3 Times / Sec.
Bandwidth 50 - 500Hz
Clamp Diameter Ø30 mm
Conductor Size (mm) 10 × 50 mm
Battery 2 x LR03
Battery Life Approx. 40 hrs. (Backlight off)
Safety Standards IEC61010 CAT.III600V
Dimension (H x W x D) 208 × 69 × 38 mm