V&A Instrument -10 ~ 100mV Volt Thermocouple Process Calibrator, VA710

Shop all V&A Instrument

SKU: ME.EL.PR.00122

Model: VA710

Roll over image to zoom zoom_in
  1. V&A Instrument -10 ~ 100mV Volt Thermocouple Process Calibrator, VA710

  • Weight: 472 Grams
  • Product Type: Process Calibrators
  • Voltage Range: -10mV ~ 100mV
  • Voltage Resolution: 0.01mV
See all product information chevron_right
  • receiptGST Invoice
  • headphonesCustomer Service
  • lockSecure Payments
  • policyReturns & Warranty
  • home_pinOrder Tracking
  • paymentsBuy in Installments

15947.7 (Incl. of all taxes)

13515+ ₹2432.7 GST (18%)

MRP ₹15900

SAVE 15%



7 Business Days

1 Set

9031

picture_as_pdfDownload Product Leafletkeyboard_double_arrow_right
picture_as_pdfBrand Authorization Certificatekeyboard_double_arrow_right
picture_as_pdfDownload Bosch Cataloguekeyboard_double_arrow_right

Highlights

Thermocouple Calibrator is a exactitude measurement and source handhold instrument, it can be use to calibrate the Thermocouple instrument. Thermocouple Calibrator can measure or simulate 8 types of difference Thermocouple (°C or °F) and measure or simulate the millivolt. But it could not use to measurement or source at a same time.


Features:

  • Measure or simulate the millivolt and 8 types of Thermocouple (? or ?)
  • Large 5-digit LCD with full angle
  • High Accuracy Max.up to 0.3°C and 0.025% mV
  • With standard jack for external power supply
  • Maximum voltage applied between any jack and earth ground or between any two jack: 30V
  • Temperature coefficient: ±0.02%/°C on 0°C~18°C and 28°C~50°C
  • Relative humidity: 95% up to 30°C, 75% up to 40°C,45% up to 50°C
  • Thermocouple Process Calibrator is a exactitude measurement and source handhold instrument, it can be use to calibrate the Thermocouple instrument.


Maintenance:

CleaningPeriodically wipe the case with a damp cloth and detergent; do not use abrasives or solvents.
CalibrationCalibrate your calibrator once a year to ensure that it performs according to its specifications.
Replacing the Battery
  • Please change the battery when the LCD indicates 
  • Turn off the power of the Calibrator, When you change the battery, and screw off the breechblock on the battery cabinet cover, then take off it and instead the fresh battery.
  • Replacing a Fuse
Warning
  • To avoid personal injury or damage to the calibrator, use only a 0.125A 250V fast fuse.
  • In the thermocouple input mode, if ‘OL’ does not appears on LCD with no thermocouple input, the fuse is probably blown. A new fuse should be used.
  • Connect wire: Use the accessories thermocouple plug to make the difference plug connect wire which you want.


Package Content:

  • 1x Calibrator
  • 2x Thermocouple plugs (no wire),
  • 6x AAA 1.5V Battery,
  • 1x user’s manual

Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.

Specifications

SKUME.EL.PR.00122
Product TypeProcess Calibrators
Model NoVA710
Voltage Range -10mV ~ 100mV
Voltage Resolution 0.01mV
Voltage Accuracy ±(0.025%+2)
Storage Temperature -40°C ~ 60°C
Operating Temperature 0°C ~ 50°C
Operating Altitude 3000 Meters (max.)
Shock Random 2g, 5Hz to 500Hz
Safety 1 Meter Drop Test
Fuse F 0.125A/250V
Thermocouple Type J, K, T, E, R, S, B, N
Temperature Resolution 0.1/0.1
Temperature Error ±(0.3+10µV)
LCD Size 64 × 42 mm
Power Requirements 6 x AAA 1.5 Batteries
Dimensions (L x W x H) 205 × 98 × 46 mm