Rishabh 3-3/4 Digit / 3999 Counts Digital Clamp Meter, RISH Clamp ES400 AC

Shop all Rishabh

SKU: ME.EL.CL.00206

Model: RISHCLAMP-ES400AC

Roll over image to zoom zoom_in
  1. Rishabh 3-3/4 Digit / 3999 Counts Digital Clamp Meter, RISH Clamp ES400 AC

  • Weight: 600 Grams
  • Product Type: Clamp Meters
  • Display Digit: 3-3/4 Digit
  • Display Counts: 3999 Count
  • Jaw Opening (mm): 41 mm
See all product information chevron_right
  • receiptGST Invoice
  • headphonesCustomer Service
  • lockSecure Payments
  • policyReturns & Warranty
  • home_pinOrder Tracking
  • paymentsBuy in Installments

3045.58 (Incl. of all taxes)

2581+ ₹464.58 GST (18%)

MRP ₹3585

SAVE 28%



3 Business Days

1 Pcs

90303390

picture_as_pdfDownload Product Leafletkeyboard_double_arrow_right
picture_as_pdfBrand Authorization Certificatekeyboard_double_arrow_right
picture_as_pdfDownload Bosch Cataloguekeyboard_double_arrow_right

Highlights

Rish Clamp ES measure Important parameters like AC current & voltage, DC voltage, Capacitance, Ohm & continuity, Frequency and duty cycle and temperature measurement.


Features:

  • RISH Clamp ES400 AC is a highly innovative design for features those increases safety and comfort of user.
  • Rotating clamp jaws facilitate the measurement at physically awkward positions, vertical bus bars, conductors placed at positions difficult to access.
  • Clamp jaws can be opened or closed with the trigger placed at bottom side away from the jaws. This allows the user to place his/her hand at safer distance from live conductor. This greatly reduces exposure of human beings to electrical shocks 
  • Location and design of trigger eliminates fatigues caused by  single finger operation. It allows spreading the force  required  to open the jaws over more than one finger to ensure  comfortable operation.
  • Comfortable operation of push buttons and function selector switch, in adverse field conditions.
  • Large Jaw Opening: For RISH Clamp ES400 AC Jaw opening of 41 mm for standard wire diameter of 40mm for 400A
  • Narrow Body: Narrow housing for firm grip and easy to carry.
  • High Accuracy for low current measurement: The clamp meter can measure accurately at not only the High currents but also Low current ranges.
  • User selectable Backlit: It is possible to conduct measurement using the clamp meter during night time in darkness with the help of Backlit. 
  • Temperature measurement: Temperature from 0 to 1300 °C using K type thermocouple sensors.
  • Auto Power Off: In order to save the power of the Batteries, the clamp meter will automatically shut OFF if it detects no activity for 15 minutes.
  • Relative Measurement: By pressing REL key, the zero correction is made and relative value is measured. All functions can measure Relative value except Hz/Duty.
  • Hold Function: By pressing HOLD key reading on the display can be latched. Simultaneously HOLD is displayed on display.
  • Hz / Duty: The instrument can measure frequency (Hz) and Duty cycle (%) of AC voltage by pressing yellow key in VAC function.
  • NULL ZERO: Correction for Resistance For Low ohm measurement, the lead resistance can be compensated by pressing REL key.
  • Non contact voltage (NCV) detection: Presence of AC voltage >75 V AC 50/60 Hz can be detected by keeping jaws near voltage carrying conductor. It is indicated by beep sound.
  • AUTO and MANUAL ranging modes: In AUTO ranging mode the instrument automatically selects the range with best resolution depending on the applied input. In MANUAL ranging mode range is user selectable using MAN key.
  • Diode and continuity testing: For testing diode and transistors, diode measurement function is available. Continuity test generates beep sound if resistance is less than 75 ohm
  • Protection from dust and water: IP20 for terminals as per IEC60529
  • Applicable International Safety standards: 600 V CAT III/1000V CAT II as per International Safety standard IEC 61010-1- 2010
  • Double moulded Cover for soft touch and firm grip of the Instrument: For testing diode and transistors, diode measurement function is available. Continuity test generates beep sound if resistance is less than 75 ohm (Diode and continuity testing) / Presence of AC voltage >75 V AC 50/60 Hz can be detected by keeping jaws near voltage carrying conductor. (Non contact voltage (NCV) detection)


Reference conditions for Accuracy:

  • Reference temperature: 23°C ± 2K
  • Relative Humidity:  45% - 55%RH
  • Waveform of measured quantity: Sinusoidal
  • Input frequency: 50 or 60 Hz ±2%
  • Battery Voltage:  3V ± 0.1V


Battery:

  • Battery Voltage: 1.5 x 2 V AAA size batteries
  • Battery Type: Zinc-Carbon Cell or Alkaline Manganese Cell per IEC 6LR03
  • Battery Life: 200 hrs (Zinc Carbon Cell) / 400 hrs (Alkaline Manganese Cell)

Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.

Specifications

SKUME.EL.CL.00206
Product TypeClamp Meters
Model NoRISHCLAMP-ES400AC
Display Digit 3-3/4 Digit
Display Counts 3999 Count
Jaw Opening (mm) 41 mm
Operating Temperature -10 to +50°C
Storage Temperature -25 to +70°C
Relative Humidity 45 - 75% Non Condensing
Protection IP52 (For Housing) / IP20 (For Terminals)
Pollution Degree 2
Installation Category 600V (CATIII) / 1000V (CATII)
High Voltage Test 4.4kV AC, 50Hz for 1 Minute Between Housing & Input
Dimensions (L x W x H) 270 x 90 x 70 mm

Shop By Related Categories

Rishabh 3-3/4 Digit / 3999 Counts Digital Clamp Meter, RISH Clamp ES400 AC

Visit Rishabh Store keyboard_double_arrow_right

3045.58 (Incl. of all taxes)

2581+ ₹464.58 GST (18%)

MRP ₹3585

SAVE 28%