  • Weight: 230 Grams
  • Product Type: Process Calibrators
  • Sampling Time: 2-3 times / second
  • Overload Protection: 50mA/30V
See all product information chevron_right
  • receiptGST Invoice
  • headphonesCustomer Service
  • lockSecure Payments
  • policyReturns & Warranty
  • home_pinOrder Tracking
  • paymentsBuy in Installments

10723.84 (Incl. of all taxes)

9088+ ₹1635.84 GST (18%)

MRP ₹13365

SAVE 32%



5 Business Days

1 Pcs

90318000

picture_as_pdfDownload Product Leafletkeyboard_double_arrow_right
picture_as_pdfBrand Authorization Certificatekeyboard_double_arrow_right
picture_as_pdfDownload Bosch Cataloguekeyboard_double_arrow_right

Highlights

The Metravi CAL-400T is a high-precision Universal Calibrator, designed for professionals who require versatile and reliable calibration for electrical and temperature measurements. This advanced device supports 100mV/30V DC Voltage measurement, 20mA DC Current measurement, and switching value measurement, ensuring accurate diagnostics and troubleshooting. Beyond measurement, the Metravi CAL-400T offers 100mV/30V DC Voltage Output, 20mA DC Current output, and SIMULATE output, making it ideal for testing and calibration applications. It features manual step and automatic waveform output, with a simultaneous display of Voltage (V), Current (mA), and percentage for enhanced convenience.

Equipped with a loop detection function, this calibrator provides a 24 V loop power supply while measuring current, essential for process control and industrial automation. Additionally, it supports eight thermocouple types (R, S, B, K, E, J, T, and N) for both measurement and output, along with temperature display in Celsius and Fahrenheit. With automatic and manual cold junction compensation, it ensures precise temperature calibration. Built for safety and durability, the Metravi CAL-400T includes overload protection, making it a robust and indispensable tool for instrumentation engineers, process control specialists, and maintenance professionals.


Technical Data For 'Measure' & 'Source':

MEASURE

  • DC Voltage Range: 100mV: -10.0mV~110.0mV, Resolution 100uV / 30V: -5.00V~30.00V, Resolution 10mV (Accuracy: 0.2%+4)
  • DC Current Range: 20mA: 0.00mA~22.00mA, Resolution 0.01mA (Accuracy: 0.2%+4)
  • Temperature / Thermocouple Ranges: Type R: 0° ~ 1760°C / Type S: 0° ~ 1760°C / Type B: 400° ~ 1820°C / Type K: -200° ~ 1370°C / Type E: -200° ~ 1000°C / Type J:  -200° ~ 1200°C / Type T: -200° ~ 400°C / Type N: -200° ~ 1300°C
  • Resolution: 1°C
  • Accuracy: 0.2% + 4

SOURCE

  • DC Voltage Range: 100mV: 0.0mV~110.0mV, Resolution 100uV / 10V: 0.00V~11.00V, Resolution 10mV (Accuracy: 0.2%+4)
  • DC Current Range: 20mA: 0.00mA~22.00mA, Resolution 0.01mA (Accuracy: 0.2%+4)
  • Analogue Transmitter SIMULATE: -20mA: 0.00mA~22.00mA, Resolution 0.01mA (Accuracy: 0.2%+4)
  • Loop Power Supply: 24V
  • Accuracy: ±10%
  • Temperature / Thermocouple Ranges: Type R: 0° ~ 1760°C / Type S: 0° ~ 1760°C / Type B: 400° ~ 1800°C / Type K: -200° ~ 1350°C / Type E: -200° ~ 700°C / Type J:  -200° ~ 950°C / Type T: -200° ~ 400°C / Type N: -200° ~ 1300°C
  • Resolution: 1°C
  • Accuracy: 0.2% + 4
  • Capacitive Load: ≥ 0.01μF


Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.

Specifications

SKUME.EL.PR.00127
Product TypeProcess Calibrators
Model NoCAL400T
Sampling Time 2-3 times / second
Overload Protection 50mA/30V
Overrange Display OL
Power Source 3 x 1.5V ( LR03/AAA ) Alkaline Batteries
Low Battery Indication Shows Battery Sign
Auto Shutdown After 15 Min of Non-operation
Warm-up Time 10 mins
Calibration Cycle 1 Year
Working Environment 0° ~ 40°C ; below 85% RH (no condensation)
Storage Environment -20° ~ 60°C ; below 90% RH (no condensation)
Accuracy Defined as per Environment 23°C±5°C; below 75% RH (no condensation)
Temperature Coefficient 0.1 × basic precision / °C (temperature range <18°C or >28°C)
Ambient Condition for Usage Indoor and outdoor use (not waterproof), with an elevation of 0~2000 m
Power Consumption When alkaline battery is used: Loop current measurement and DC current output (SOURCE) 20mA (a load of 1000O): approx. 1000mVA Other work function: approx. 300mVA