- DC Voltage Range: 600.0 mV to 1000 V, 5 Ranges
- AC Voltage Range: 6.000 V to 1000 V, 4 Ranges
- receiptGST Invoice
- headphonesCustomer Service
- lockSecure Payments
- policyReturns & Warranty
- home_pinOrder Tracking
- paymentsBuy in Installments
₹17329.48 (Incl. of all taxes)
₹14686+ ₹2643.48 GST (18%)
MRP ₹18357
SAVE 20%
5 Business Days
1 Pcs
9030
picture_as_pdfDownload Product Leafletkeyboard_double_arrow_right
picture_as_pdfBrand Authorization Certificatekeyboard_double_arrow_right
picture_as_pdfDownload Bosch Cataloguekeyboard_double_arrow_right
picture_as_pdfBrand Authorization Certificatekeyboard_double_arrow_right
picture_as_pdfDownload Bosch Cataloguekeyboard_double_arrow_right
Highlights
The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level.
The DT4253 is a digital multimeter designed specifically for HVAC testing, with ±0.5% DC V accuracy, temperature and clamp sensor testing, and wide 40 Hz to 1 kHz bandwidth.
Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.
The DT4253 is a digital multimeter designed specifically for HVAC testing, with ±0.5% DC V accuracy, temperature and clamp sensor testing, and wide 40 Hz to 1 kHz bandwidth.
- Display: Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph
- Display refresh rates: 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s)
Key Features:
- Ideal for measuring currents ranging from instrumentation signals (4 to 20 mA) to flame currents (μA) with built in high-sensitivity current ranges (DT4253)
- Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
- Dual display lets you check voltage and frequency simultaneously
What's Included In This Package:
- 1x Test lead L9207-10
- 1x Holster
- 1x Instruction manual
- 1x LR03 alkaline battery
Digital multimeter ideal for instrumentation, airconditioning equipment, and gas-burning devicesThe DT4253, which is part of Hioki’s DT4250 series of standard digital multimeters, is ideal for measuring instrumentation, airconditioning equipment, and gas-burning devices.
|
600.00 μA range for measuring very low currents used by gas-burning devicesAccurately measure the very low currents such as burner flame currents. |
Percentage display for instrumentation signal 4 to 20 mA measurementsThe instrument can convert and display instrumentation signals of 4 to 20 mA or 0 to 20 mA representing properties such as temperature, pressure, and flow rate from a transducer or other device that converts sensor data into an electrical signal. |
Clamp-on sensor based current measurement eliminates the cause of accidentsMistakenly measuring voltage using the current range may lead to a short-circuit. The DT4253 eliminates the root cause of such accidents by providing clamp-on sensor based current measurement functionality instead of using conventional probes. |
Measurement data can be downloaded to, reviewed on, and saved to a computer.If you connect the DT4253 to a computer with the optional Communication Package DT4900-01, you can graph data stored in the instrument’s internal memory and display measurement results in real time on the computer. In addition, displayed measured values can be saved (in text format).*The computer and multimeter are electrically isolated by means of optical communications so that data can be sent with peace of mind. |
Measure output voltage on the secondary sides of inverters by eliminating harmonic componentsAccurately measure the fundamental wave alone by eliminating harmonic components with the DMM’s low-pass filter function. |
True RMS measurement for accurate measurement of even distorted current waveformsDigital multimeters implement two types of measurement: mean-value measurement and true RMS measurement.The two methods yield significantly different measurement results for current waveforms, which are often distorted. For accurate measurement, it is necessary to use an instrument with true RMS capability. |
Designed and manufactured in Japan to ensure high quality and guaranteed with a 3-year warranty for peace of mindAll development, design, and manufacturing processes for almost all Hioki digital multimeters are carried out at our Head Office in Nagano Prefecture. Some of the industry’s most advanced technological capabilities enable us to deliver products of the highest possible quality. |
Safe measurement requires use of an instrument that suits the measurement locationTo ensure operators’ ability to use measuring instruments safely, IEC 61010 classifies the locations in which instruments are used into a series of safety-based measurement categories (ranging from CAT II to CAT IV). Using an instrument that does not satisfy the required safety level can lead to an electrical accident. Despite a compact body, the DT4222 can be used to measure voltage at distribution panels. |
Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.
Specifications
SKU | ME.EL.MU.00041 |
---|---|
Product Type | Multimeter |
Model No | DT4253 |
Power supply | LR03 Aalkaline Batteries |
DC Voltage Range | 600.0 mV to 1000 V, 5 Ranges |
DC Voltage Range (Basic Accuracy) | ±0.3 % rdg. ±5 dgt. |
AC Voltage Range | 6.000 V to 1000 V, 4 Ranges |
AC Voltage Range (Basic Accuracy 40 - 500 Hz) | ±0.9 % rdg. ±3 dgt. (True RMS, Crest Factor 3) |
DC Current Range | 60.00 µA to 60.00 mA, 4 Ranges |
DC Current Range (Basic Accuracy) | ±0.8 % rdg. ±5 dgt. |
AC Current Range (Use With Clamp On Probes) | 10.00 A to 1000 A, 7 Ranges |
AC Current Range (Add the Clamp on Probe Accuracy to Basic Accuracy 40 - 1 kHz) | ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
Frequency Range | 99.99 Hz to 99.99 kHz, 4 Ranges (Limited by The Minimum Detectable Voltage) |
Frequency Range (Basic Accuracy) | ±0.1 % rdg. ±1 dgt. |
Frequency Characteristics | 40 Hz - 1 kHz |
Continuity Check (Continuity Threshold [ON]) | 25 Ohm or Less (Buzzer Sound) |
Continuity Check (Continuity Threshold [OFF]) | 245 Ohm or More Response Time: 0.5 ms or More |
Resistance Range | 600.0 Ohm to 60.00 M Ohm, 6 Ranges |
Resistance Range (Basic Accuracy) | ±0.7 % rdg. ±5 dgt. |
Capacitance Range | 1.000 µF to 10.00 mF, 5 Ranges |
Capacitance Range (Basic Accuracy) | ±1.9 % rdg. ±5 dgt. |
Diode Test | Open Terminal Voltage: 5.0 V or Less, Testing Current 0.5 mA or Less, Threshold of Forward Voltage: 0.15 V to 1.5 V |
Temperature (Thermocouples) | -40.0 to 400.0 °C |
Temperature (Thermocouples) (Basic Accuracy) | ±0.5 % rdg. ±2 °C |
Battery Usage | Continuous Use 130 hours (Back Light OFF) |
Length x Width X Height | 84 mm × 174 mm × 52 mm |
Other Functions | Filter Function, Display Value Hold, Auto Hold, MAX/MIN/Average Value Display, Relative Value Display, Auto-Power Save, USB Communication (option), 4-20 mA Percentage Conversion |