Hioki 60000 Count Premier Pocket Digital MultiMeter, DT4282
Roll over image to zoom zoom_in

- Weight: 650 Grams
- Product Type: Multimeter
- Power supply: LR6 (AA) Alkaline Batteries
- DC Voltage Range: 60.000 mV to 1000.0 V, 6 Ranges
- AC Voltage Range: 60.000 mV to 1000.0 V, 6 Ranges
- receiptGST Invoice
- headphonesCustomer Service
- lockSecure Payments
- policyReturns & Warranty
- home_pinOrder Tracking
- paymentsBuy in Installments
₹32746.18 (Incl. of all taxes)
₹27751+ ₹4995.18 GST (18%)
MRP ₹34689
SAVE 20%
5 Business Days
1 Pcs
9030
picture_as_pdfDownload Product Leafletkeyboard_double_arrow_right
picture_as_pdfBrand Authorization Certificatekeyboard_double_arrow_right
picture_as_pdfDownload Bosch Cataloguekeyboard_double_arrow_right
picture_as_pdfBrand Authorization Certificatekeyboard_double_arrow_right
picture_as_pdfDownload Bosch Cataloguekeyboard_double_arrow_right
Highlights
The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket types.
The DT4282 is a high-precision 60,000 count digital multimeter with direct 10A input and all of the functions and features required for advanced testing in laboratories and R&D.
Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.
The DT4282 is a high-precision 60,000 count digital multimeter with direct 10A input and all of the functions and features required for advanced testing in laboratories and R&D.
- Display: Main and sub displays: 5-digits LCD, max. 60000 digits
- Display refresh rates: 5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s )
Key Features:
- 60000 count, 5-digit display, high-resolution measurements
- Measures large currents with optional clamp probe (only for DT4282, which has no 10 A terminal for accident prevention)
- ±0.025% DC V basic accuracy, wide 20 Hz to 100 kHz AC V frequency characteristics
- Terminal shutter mechanism (prevents erroneous test lead insertion)
- Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
- Dual display lets you check voltage and frequency simultaneously
What's Included In This Package:
- 1x Test lead L9207-10
- 1x Instruction manual
- 4x LR6 Alkaline Battery
The ultimate digital multimeter, ideal for use R&D applicationsThe DT4282, which is part of Hioki’s DT4280 series of high-end digital multimeters, is designed for use in laboratories and R&D applications where you wish to measure a wide variety of parameters.
|
Measure output voltage on the secondary sides of inverters by eliminating harmonic componentsAccurately measure the fundamental wave alone by eliminating harmonic components with the DMM’s low-pass filter function. |
Measure the ripple voltage of DC charging systemsYou can measure ripple voltage with a superposed DC signal by using peak value measurement and DC + AC voltage measurement. |
Percentage display for 4 to 20 mA instrumentation signalsThe digital multimeter can convert and display instrumentation signals of 4 to 20 mA or 0 to 20 mA representing properties such as temperature, pressure, and flow rate from a transducer or other device that converts sensor data into an electrical signal. |
600.00 μA range for measuring very low currents used by gas-burning devicesAccurately measure the very low currents such as burner flame currents. |
True RMS measurement for accurate measurement of even distorted current waveforms
|
Measurement data can be downloaded to, reviewed on, and saved to a computer.Connect the DT4282 to a PC with the optional Communication Package DT4900-01 to easily graph data stored in the DMM’s internal memory and display measurement results in real time on the computer. Save important measured values in text format.*The computer and multimeter are electrically isolated by means of optical communications so that data can be sent without concern for electrical hazards. |
Designed and manufactured in Japan to ensure high quality and guaranteed with a 3-year warranty for peace of mindAll development, design, and manufacturing processes for almost all Hioki digital multimeters are carried out at our Head Office in Nagano Prefecture. Some of the industry’s most advanced technological capabilities enable us to deliver products of the highest possible quality. |
Safe measurement requires use of an instrument that suits the measurement location.To ensure operators’ ability to use measuring instruments safely, IEC 61010 classifies the locations in which instruments are used into a series of safety-based measurement categories (ranging from CAT II to CAT IV). Using an instrument that does not satisfy the required safety level can lead to an electrical accident. |
Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.
Specifications
SKU | ME.EL.MU.00046 |
---|---|
Product Type | Multimeter |
Model No | DT4282 |
Power supply | LR6 (AA) Alkaline Batteries |
DC Voltage Range | 60.000 mV to 1000.0 V, 6 Ranges |
DC Voltage Range (Basic Accuracy) | ±0.025 % rdg. ±2 dgt. |
AC Voltage Range | 60.000 mV to 1000.0 V, 6 Ranges |
AC Voltage Range (Basic Accuracy 45 - 65 Hz) | ±0.2 % rdg. ±25 dgt. (True RMS, Crest Factor 3) |
DC Current Range | 600.00 µA to 600.00 mA, 6 Ranges |
DC Current Range (Basic Accuracy) | ±0.05 % rdg. ±5 dgt. |
AC Current Range | 600.00 µA to 600.00 mA, 6 Ranges |
AC Current Range (Basic Accuracy 45 - 65 Hz) | ±0.6 % rdg. ±5 dgt. (True RMS, Crest Factor 3) |
DC + AC Voltage* Range | 6.0000 V to 1000.0 V, 4 Ranges |
DC + AC Voltage* Range (Basic Accuracy 45 - 65 Hz) | ±0.3 % rdg. ±30 dgt. (True RMS, Crest Factor 3) |
Frequency Range | AC V, DC+AC V, AC A Measurement, at Pulse Width 1 µs or More (50 % Duty Ratio) 99.999 Hz (0.5 Hz or More) to 500.00 kHz, 5 Ranges |
Frequency Range (Basic Accuracy) | ±0.005 % rdg. ±3 dgt. |
Frequency Characteristics | 20 Hz - 100 kHz |
Continuity Check (Continuity Threshold) | 20/50/100/500 O, Response Time: 10 ms or More |
dB Conversion | Standard Impedance Setting (dBm), 4 Ohm to 1200 Ohm, 20 Stages Display dB Conversion Value of AC voltage (dBV) |
Resistance Range | 60.000 Ohm - 600.0 M Ohm, 8 Ranges |
Resistance Range (Basic Accuracy) | ±0.03 % rdg. ±2 dgt. |
Capacitance Range | 1.000 nF to 100.0 mF, 9 Ranges |
Capacitance Range (Basic Accuracy) | ±1.0 % rdg. ±5 dgt. |
Diode Test | Open Terminal Voltage: 4.5 V or Less, Testing Current 1.2 mA or Less, Threshold of Forward Voltage: 0.15 V to 3 V, Seven Stages |
Peak (DC V Measurement) | Signal Width 4 msec or More (Single), 1 msec or More (Repeated) |
Peak (AC V, DC/AC A Measurement) | Signal Width 1 msec or More (Single), 250 µsec or More (Repeated) |
Temperature (Thermocouples) | -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F) Add Accuracy of The Thermocouple Probe to Main Unit Accuracy: ±0.5 % rdg. ±3 °C |
Battery Usage | Continuous Operating Time: 100 hrs |
Length x Width x Height | 93 mm × 197 mm × 53 mm |
Other Functions | Filter Function (Remove Harmonic Noise, Use Only at 600 V AC, 1000 V AC Ranges), Display Value Hold, Auto Hold, MAX/MIN Value Display, PEAK Value Display, Relative Value Display, Sampling Setting, Internal Memory (400 Data), Auto-Power Save, USB Communication (Option), Mis-Insertion Prevention Shutters, Decibel Conversion, 4-20 mA Percentage Conversion |
Shop By Related Categories
Hioki 60000 Count Premier Pocket Digital MultiMeter, DT4282
Visit Hioki Store keyboard_double_arrow_right₹32746.18 (Incl. of all taxes)
₹27751+ ₹4995.18 GST (18%)
MRP ₹34689
SAVE 20%