Hioki 6000 Count Premier Pocket Digital MultiMeter, DT4261

Shop all Hioki

SKU: ME.EL.MU.00044

Model: DT4261

Roll over image to zoom zoom_in
  1. Hioki 6000 Count Premier Pocket Digital MultiMeter, DT4261
  2. Hioki 6000 Count Premier Pocket Digital MultiMeter, DT4261

  • Weight: 480 Grams
  • Product Type: Multimeter
  • Power supply: LR6 (AA) Alkaline Batteries
  • DC Voltage Range: 600.0 mV to 1000 V, 5 Ranges
  • AC Voltage Range: 6.000 V to 1000 V, 4 Ranges
See all product information chevron_right
  • receiptGST Invoice
  • headphonesCustomer Service
  • lockSecure Payments
  • policyReturns & Warranty
  • home_pinOrder Tracking
  • paymentsBuy in Installments

23903.26 (Incl. of all taxes)

20257+ ₹3646.26 GST (18%)

MRP ₹25321

SAVE 20%



5 Business Days

1 Pcs

9030

picture_as_pdfDownload Product Leafletkeyboard_double_arrow_right
picture_as_pdfBrand Authorization Certificatekeyboard_double_arrow_right
picture_as_pdfDownload Bosch Cataloguekeyboard_double_arrow_right

Highlights

Hioki mid-range DMM, the DT4261, is an exceptional support tool with multifaceted functionality designed to help analyze a variety of issues and boost work efficiency.
 
  • Display: Main and Sub displays: 4-digits LCD, max. 6000 digits (excluding frequency measurement), bar-graph
  • Display refresh rates: 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s)


Key Features:

  • Helping personnel analyze issues in the field
  • Stop worrying about losing test lead capsDual display lets you check voltage and frequency simultaneously
  • Boost work efficiency with digitalization (Excel® Direct Input Function)
  • Excellent dust and water resistance (compliant with the IP54 international standard)
  • Ensuring safety by preventing erroneous test lead insertion (terminal shutters)
 

What's Included In This Package:

  • 1x Test lead L9300
  • 1x Operating Precautions
  • 1x Instruction manual
  • 3x LR6 (AA) Alkaline Battery
 

Safe inspection of solar installations with high voltage

DC High V Probe Mode
  • Enables high voltage measurement up to CAT III 2000 V
  • Safely measure solar installations like the mega-solar without interrupting the grid by simply connecting the DC High Voltage Probe P2000 to compatible Hioki clamp meters and digital multimeters (DMMs)

Helping personnel analyze issues in the field

Harmonic measurement: When combined with GENNECT Cross (*1), you can perform simple harmonic analysis. Applications include harmonic measurement of power conditioners for solar systems and problem analysis of power supply systems.

Wireless communication capability for even greater convenience

Wireless support: When the Wireless Adapter Z3210 is installed, Bluetooth® wireless communication is enabled. It transfers measurements to your smartphone or tablet and allows you to quickly create reports with field photos and drawings.

Prevents incorrect current measurement

Fuse check function: When switching from the clamp function to the current function, a fuse disconnection check is automatically performed. This allows the user to know if the fuse is broken before current measurement, which prevents erroneous measurement.

Ensuring safety by preventing erroneous test lead insertion

Terminal shutters: Due to the current terminal’s low impedance, measuring voltage after erroneously inserting a test lead into the current terminal will cause the fuse to blow. The DT4261’s terminal shutters are linked to the instrument’s rotary switch such that they block access to test lead terminals that aren’t being used, making it physically impossible to insert a lead into the wrong terminal.

Multifaceted functionality and performance for a variety of tasks

  • Ability to withstand being dropped onto concrete from a height of 1 m (drop-proof design)
  • Broad operating temperature range of -25°C to 65°C
  • Automatic detection of DC and AC voltages (AUTO V function)
  • Visual warning of excessive input via red backlight
  • Visual indication of HOLD operation via orange light

Safe measurement requires use of an instrument that suits the measurement location

To ensure operators’ ability to use measuring instruments safely, IEC 61010 classifies the locations in which instruments are used into a series of safety-based measurement categories (ranging from CAT II to CAT IV). Using an instrument that does not satisfy the required safety level can lead to an electrical accident. Despite a compact body, the DT4222 can be used to measure voltage at distribution panels.

Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.

Specifications

SKUME.EL.MU.00044
Product TypeMultimeter
Model NoDT4261
Power supply LR6 (AA) Alkaline Batteries
DC Voltage Range 600.0 mV to 1000 V, 5 Ranges
DC Voltage Range (Basic Accuracy) ±0.15% rdg. ±2 dgt.
AC Voltage Range 6.000 V to 1000 V, 4 Ranges
AC Voltage Range (Basic Accuracy 40 - 500 Hz) ±0.9 % rdg. ±3 dgt. (True RMS, Crest Factor 3 or Less)
DC Current Range 60.00 mA - 10.00 A, 3 Ranges
DC Current Range (Basic Accuracy) ±0.5% rdg. ±3 dgt.
AC Current Range 600.0 mA - 10.00 A, 3 Ranges
AC Current Range (Basic Accuracy 40 - 500 Hz) ±1.4 % rdg. ±3 dgt. (True RMS, Crest Factor 3, 40 Hz to 1 kHz)
AC Current Range (Use With Clamp On Probes) 10.00 A to 1000 A, 7 Ranges
AC Current Range (Add the Clamp on Probe Accuracy to Basic Accuracy 40 - 500 Hz) ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
Current Frequency Range 99.99 Hz to 9.999 kHz, 3 Ranges (Limited by Minimum Sensitivity Current)
Frequency Range (Basic Accuracy) ±0.1 % rdg. ±1 dgt.
Frequency Characteristics 40 Hz - 1 kHz
Continuity Check (Continuity Threshold [ON]) 25 Ohm or Less
Continuity Check (Continuity Threshold [OFF]) 245 Ohm or More Response Time: 0.5 ms or More
Resistance Range 600.0 Ohm to 60.00 M Ohm, 6 Ranges
Resistance Range (Basic Accuracy) ±0.7 % rdg. ±3 dgt.
Capacitance Range 1.000 µF to 10.00 mF, 5 Ranges
Capacitance Range (Basic Accuracy) ±1.9 % rdg. ±5 dgt.
Diode Test Open Terminal Voltage: 2.0 V or Less, Testing Current: 0.2 mA or Less, Threshold of Forward Voltage: 0.15 V to 1.8 V
LoZ V 600.0 V, 1 Range
LoZ V (Basic Accuracy DC, 40 Hz - 500 Hz) ±1.0% rdg. ±13 dgt. (True RMS, Crest Factor 3 or Less)
Battery Usage Continuous Operating Time: 130 hr. (Without Z3210 Installed), 70 hr. (With Z3210 Installed and Using Wireless Communications)
Length x Width X Height 87 mm × 185 mm × 47 mm
Other Functions Mis-insertion prevention shutters, fuse check function, user setting retention function, filter function, zero-adjustment, display value hold, auto hold, MAX/MIN value display, PEAK value display, auto-power save, USB communication (when optional Communication Package DT4900-01 is installed), wireless communication (when optional Wireless Adapter Z3210 is installed)

Shop By Related Categories